Scytek-electronics PRECISION PRO 5500 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Alarm samochodowy Scytek-electronics PRECISION PRO 5500. ScyTek Electronics PRECISION PRO 5500 User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 52
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
PRECISION PRO
5500
VEHICLE SECURITY SYSTEM
WITH REMOTE START
PRECISION PRO
2200
REMOTE START ONLY
PRODUCT MANUAL
Przeglądanie stron 0
1 2 3 4 5 6 ... 51 52

Podsumowanie treści

Strona 1 - PRECISION PRO

PRECISION PRO5500VEHICLE SECURITY SYSTEMWITH REMOTE START PRECISION PRO2200REMOTE START ONLYPRODUCT MANUAL

Strona 2 - Warranty

Setting AutoStart Cold Temperature ThresholdSelect Cold Temp start setting by pressing buttons 1 or 2 to highlight the feature. Press button 3 to sel

Strona 3 - Contents

Page 7 - Color RemoteSelect Clock Sync setting by pressing buttons 1 or 2 to highlight the pager. Press button 3 to select thepager.Pager Clock SyncT

Strona 4

Page 8 - Color RemoteUse buttons 1 & 2 to highlight Set Time press button 3.The security system responce.Start Time 2This feature sets the system

Strona 5 - System Contents:

Pressing and holding transmitter button 5 will scroll through several transmitter programmableoptions - TEMPERATURE, ENABLE COLD START, ENABLE HOT STA

Strona 6

Transmitter LockoutPress and hold buttons 2 & 4 simultanously for 3seconds to lockout the transmitter against accidentaltransmission.Release Trans

Strona 7 - PARAMETERS

Time: time of day clockDate/Engine Run Timer: date, or engine run minute timer if remote start activated (20 minmax).Battery Status: displays remainin

Strona 8 - Selecting Sound/Vibration

Standard Remote Transmitter DescriptionThe Precision 5500, 2200 Series is supplied with one 5-button Remote Transmitter that is used to controlthe sy

Strona 9 - Parameters

Adding/Replacing Standard Remote Transmitters To replace lost or stolen transmitters or to add additional transmitters into the system, have all desi

Strona 10 - Page 6 - Color Remote

2-way LCD Remote Transmitter DescriptionThe Precision 5500 and 2200 are supplied with a 2-way LCD remote transmitter, offering increased rangeand con

Strona 11 - Start Time 1

3. Press and release Button 1 on the first transmitter, then on the second transmitter.· The siren*/horn will chirp/honk once for every transmitter l

Strona 12 - Start Time 2

Limited Lifetime WarrantyThis system is warranted to the original purchaser, to be free from defects in material andworkmanship. The manufacturer w

Strona 13

To set the daily start feature:1. Press and hold Buttons 2 and 3 until the remote beeps four times.· The fan and clock will be shown indicating daily

Strona 14 - FUNCTION

Precision - Page 17CHP Set the siren*/horn confirmation chirps*/honks ON or OFF:1. Press and hold Button 5 until the display shows CHP.·The transm

Strona 15 - 11/16 3:10P

Page 18 - Precision 2. Release Button 5.· The transmitter will beep once.· The LCD panel will show Auto Start Hot Temperature setting.3. Press and ho

Strona 16 - Transmitters

Precision - Page 19Remote Arming*/LockingThe system monitors 5 independent areas (zones) while armed: doors, hood/ trunk, shock sensor, optionalse

Strona 17 - Battery Replacement

Page 20 - Precision * Tamper AlertIf the system was triggered while away, the LED will flash to indicate which zone triggered the system afterdisarmin

Strona 18 - Page 14 - Precision

Precision - Page 21Panic ModeIn the event of an emergency, the transmitter’s remote Panic feature can be used to instantly trigger thealarm*/panic

Strona 19 - Setting The Alarm Clock

Page 22 - PrecisionTo Emergency Override the system using the Code:1. Follow steps 1-3 above. 2. Press the override switch a number of times equal to

Strona 20 - System Confirmation

Precision - Page 23Remote StartingTo Remote Start the System:1. Be sure the system is not in Valet Mode.2. Press and hold Button 4 for three sec

Strona 21

Page 24 - Precision ProAutomatic Start ModeAutomatic Start feature has three modes that will start the vehicle every one or two hours.1. Timer Only

Strona 22 - Page 18 - Precision

Precision Pro - Page 25Model: Precision 5500-M Precision 2200-M1- Tach wire must be connected , The system must learn RPM.2- Hand brake must be con

Strona 23 - Tamper Alert

1. About Your System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 12. Remote Tra

Strona 24 - * Passive Arming

Page 26 - Precision Extended FeaturesIgnition Door LockingFor added safety, the Ignition Door Locking feature allows vehicles equipped with power do

Strona 25 - Anti-Carjacking Protection

Precision - Page 271. Thoroughly read and become familiar with the installation instructions before beginning the installation.2. Review system cont

Strona 26 - DRIVER CALLING/PAGE FEATURE

Page 28 -Precision Mounting the Control UnitThe control unit must only be mounted in the interior of the vehicle. Do not mount the main unit inthe

Strona 27 - Features

Precision - Page 29System Wiring6-Pin Starter HarnessPin 1 RED WIRE A: Main Power Input A (+). Connect to the battery or constant power wire at th

Strona 28 - Turbo Timer Feature

Precision Pro - Page 30Page 30 - Precision Pin 11 BROWN WIRE: Siren Output (+) 3A. The Brown wire must connect to the siren’s red wire. TheBlack

Strona 29 - Turbo Timer Inhibit

Precision - Page 316-Pin White Connector: Located on the front of the main module.pin 1 VIOLET: Lock and unlock common inputpin 2 BROWN: Unlock

Strona 30 - Extended

Precision Pro - Page 32Jumper SelectionCarefully separate the top and bottom halves of the main unit case. Once the cover is removed, the parkingligh

Strona 31 - Installation

Precision Pro - Page 33Page 33 - Precision Entering System ProgrammingThis system is compatible with both the LCD two way transmitter or the standa

Strona 32 - * Mounting the Shock Sensor

Page 34 - Precision Pro Precision - Page 34Branch Feature Button 1 (default) Button 2 Button 31. Arm Mode Manual Arming Passive Arming2. Auto Rear

Strona 33 - 16-Pin Main Harness

Precision Pro - Page 355. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors whenthe ignition is turned off.

Strona 35 - Plug-in Connectors

Page 36 - Precision Pro14. Disarm with Auxiliary 1. When selected, activating the Auxiliary 1 output (usually used to openthe trunk) will disarm the

Strona 36 - All JUMPER DEFAULTS +

Precision Pro - Page 3726. Ignition 2 Relay Program. Selects one of three operating modes for the Ignition 2 relay output:Ignition 2, Accessory 2,

Strona 37 - Default Reset

Page 38 - Precision Pro Precision - Page 38System Options Starter Only SeriesBranch Feature Button 1 (default) Button 2 Button 31 Lock/Unlock

Strona 38

Precision Pro - Page 39Programmable System OptionsThe following is a description of the programming options of the system. Some of the program bran

Strona 39 - Precision Pro - Page 35

Page 40 - Precision Pro9. Auxiliary 3 Mode. Selects from momentary, 10 second timed, or latched operation for Auxiliary 3. Momentary operation pro

Strona 40 - Page 36 - Precision Pro

Precision Pro - Page 4121. RPM Learn/Tach Monitor This dual program branch sets the engine mode for Gas or Diesel, andlearns the vehicle’s RPM thres

Strona 41 - Precision Pro - Page 37

Page 42 - PrecisionRelay DiagramsPositive Dome Light ActivationNegative Dome Light ActivationPositive Horn Honk Negative Horn HonkStarter Defeat/Anti

Strona 42

Precision - Page 43Negative TriggerReverse Polarity VacuumAdding ActuatorsFollow the diagrams below for connecting basic door lock systems. For Tw

Strona 43 - Programmable System Options

Page 44 - Precision Two Stage Door Lock DiagramsTwo Stage Negative TriggerTwo Stage Positive TriggerThe Precision 5500 and 2200 Series is equipped

Strona 44 - Page 40 - Precision Pro

Precision - Page 45Two Stage Door Lock Diagrams cont’dTwo Stage Reverse PolarityTwo Stage Adding Actuators

Strona 45 - Precision Pro - Page 41

The ScyTek Precision 5500 Series is a Combination Vehicle Security and Remote Starting Systemthat will have features and functions that will be descri

Strona 46 - Diagrams

FCC ID: OARRXAM2000This device complies with Part 15 of FCC Rules.Operation is subject to the following two conditions:1) This device may not cause ha

Strona 47

Starter doesn’t start and parking lights flash:3 Times - Engine RPM not detected (check tach wire and/or perform tach learn procedure)Hood Trigger is

Strona 48 - Door Lock Inverter Blue Wire

ScyTek Electronics11627 Cantara Street North Hollywood, CA 91605www.scytek.net© ScyTek Electronics 2006 Precision 8-10-06Wiring DiagramManual Tran

Strona 49 - Two Stage Adding Actuators

The 2-way Color remote transmitter is offering increased range and confirmation of any activated feature. Page 1Button 1 Arms and Locks* the system

Strona 50 - Information

Press and hold Buttons 2 and 3 until pager program features are displayed.Select pager setting by pressing buttons 1 or 2 to highlight the pager. Pres

Strona 51 - Precision - Page 47

Page 4 - Precision ProUse buttons 1 & 2 to highlight the time parameter you wish to change, use buttons 3 & 4 to scroll up ordown to chage th

Strona 52 - Precision Pro Series

Page 5 - Color Remote Return to Previous ScreenSelect Previous Screen by pressing buttons 1 or 2 to highlight the feature. Press button 3 to select i

Komentarze do niniejszej Instrukcji

Brak uwag