Scytek-electronics 5000RS PLUS SERIES Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Alarm samochodowy Scytek-electronics 5000RS PLUS SERIES. ScyTek Electronics 5000RS PLUS SERIES User Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - 5000RS PPLUS SSERIES

5000RS PPLUS SSERIESVEHICLE SECURITY SYSTEMWITH REMOTE START PRODUCT MANUAL

Strona 2 - Limited LLifetime WWarranty

Page 6 - Galaxy 5000RS PlusRemote ArmingThe system monitors 6 independent areas (zones) while armed: doors, hood, trunk, shock sensor, optionalsensor

Strona 3 - Table oof CContents

Galaxy 5000RS Plus - Page 7Tamper AlertIf the system was triggered while away, the LED will flash to indicate which zone triggered the system afterd

Strona 4

Page 8 - Galaxy 5000RS PlusPanic ModeIn the event of an emergency the transmitter’s remote Panic feature can be used to instantly trigger thealarm.To

Strona 5 - About YYour SSystem

Galaxy 5000RS Plus - Page 9To set the Emergency Override Code:1. Turn on ignition.2. Within 5 seconds, press the valet switch 5 times.· The siren wi

Strona 6 - Remote TTransmitters

Page 10 - Galaxy 5000RS PlusRemote StartingTo Remote Start the System:1. Be sure the system is not in Valet Mode.2. Press and hold Button 4 for thr

Strona 7 - Battery Replacement

Galaxy 5000RS Plus - Page 11Automatic Start ModeThe Automatic Start Mode allows the vehicle to automatically start the vehicle every one or two hou

Strona 8 - Button 5

Page 12 - Galaxy 5000RS PlusExtended FFeaturesIgnition Door LockingFor added safety, the Ignition Door Locking feature allows vehicles equipped with

Strona 9 - Galaxy 5000RS Plus - Page 5

Galaxy 5000RS Plus - Page 131. Thoroughly read and become familiar with the installation instructions before beginning the installation.2. Review s

Strona 10 - System OOperation

Page 14 - Galaxy 5000RS PlusMounting the Control UnitThe control unit must only be mounted in the interior of the vehicle. Do not mount the main un

Strona 11 - Passive Arming

Galaxy 5000RS Plus - Page 15System WWiring6-Pin Starter HarnessPin 1 RED WIRE A: Main Power Input A (+). Connect to the battery or constant power wi

Strona 12 - Emergency Override

Limited LLifetime WWarrantyThis vehicle security system is warranted to the original purchaser, to be free from defects inmaterial and workmanship. Th

Strona 13 - Valet Mode

Page 16 - Galaxy 5000RS PlusPin 9 BLACK WIRE: Ground Input (-). The Black wire must connect to a solid chassis ground. Clean awayany paint or dirt to

Strona 14 - Remote SStart FFeatures

Galaxy 5000RS Plus - Page 17Jumper SelectionCarefully separate the top and bottom halves of the main unit case. Once the cover is removed, the park

Strona 15 - Turbo Timer Feature

Page 18 - Galaxy 5000RS PlusEntering System ProgrammingThis system is compatible with both the optional LCD transmitter or the standard AM transmitte

Strona 16 - Extended FFeatures

Galaxy 5000RS Plus - Page 195. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors whenthe ignition is turned

Strona 17 - System IInstallation

Page 20 - Galaxy 5000RS Plus10. Ignore Open Door Report. Bypasses the open zone warning chirps for vehicles equipped with aresidual dome light circui

Strona 18 - Mounting the Shock Sensor

Galaxy 5000RS Plus - Page 21FM module must be connected before completing this step. FM Remote Learn. Learns the optional 2-way FM transmitter. Pre

Strona 19 - System WWiring

Page 22 - Galaxy 5000RS PlusWiring DDiagramsTO POSITIVEDOME LIGHT+12VBlack/White(-) DOME LIGHTOUTPUTTO NEGATIVEDOME LIGHT+12VBlack/White(-) DOME LIGH

Strona 20 - Plug-in Connectors

Galaxy 5000RS Plus - Page 23Negative TriggerPositive TriggerReverse Polarity VacuumAdding ActuatorsFollow the diagrams below for connecting basic do

Strona 21 - Jumper SSettings

Page 24 - Galaxy 5000RS PlusTwo SStage DDoor LLock DDiagramsTwo Stage Negative TriggerTwo Stage Positive TriggerThe Galaxy 5000RS Plus is equipped wi

Strona 22 - System PProgramming

Galaxy 5000RS Plus - Page 25Two SStage DDoor LLock DDiagrams ccont’dTwo Stage Reverse PolarityTwo Stage Adding Actuators

Strona 23

1. About Your System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 12. Remote Tra

Strona 24 - Page 20 - Galaxy 5000RS Plus

Page 26 - Galaxy 5000RS PlusFCC ID: OARRXAM2000This device complies with Part 15 of FCC Rules.Operation is subject to the following two conditions:1)

Strona 25

Galaxy 5000RS Plus - Page 27Notes

Strona 26 - Wiring DDiagrams

ScyTek Electronics11627 Cantara Street Unit BNorth Hollywood, CA 91605© ScyTek Electronics 2003 Galaxy 5000RS r3 11/03Wiring DDiagram

Strona 28 - Two Stage Positive Trigger

The ScyTek Galaxy 5000RS Plus is a combination vehicle security and remote starting system featuring abuilt-in "ScyNet Network Port" that al

Strona 29 - Two Stage Adding Actuators

Standard Remote Transmitter DescriptionThe Galaxy 5000RS Plus is supplied with two 5-button Remote Transmitters used to control systemoperations. Not

Strona 30 - Starter DDiagnostics

Adding/Replacing Transmitters To replace lost or stolen transmitters or to add additional transmitters into the system, have all desiredtransmitters r

Strona 31

Page 4 - Galaxy 5000RS PlusOptional 2-way LCD Remote Transmitter DescriptionThe Galaxy 5000RS Plus is compatible with the optional 2-way LCD remote t

Strona 32 - Wiring DDiagram

Galaxy 5000RS Plus - Page 5LCD Transmitter Battery ReplacementYour Galaxy Remote Transmitter uses a 1.5 volt AAA alkaline battery, which will requir

Komentarze do niniejszej Instrukcji

Brak uwag